8. Operating modes
158
Festo P.BE-CMMP-CO-SW-EN 0708NH
Object 607C
h
: home_offset
The object
home_offset
establishes the displacement of the zero position compared to
the determined homing position.
Home
Position
home_offset
Zero
Position
Fig. 8.2: Home Offset
Index
607C
h
Name
home_offset
Object code
VAR
Data Type
INT32
Access
rw
PDO Mapping
yes
Units
position units
Value Range
--
Default Value
0
Object 6098
h
: homing_method
A series of different methods are provided for a homing run. Through the object
homing_method
, the variant needed for the application can be selected. There are four
possible homing run signals: the negative and positive limit switch, the homing switch
and the (periodic) zero pulse of the angle encoder. In addition, the motor controller can
reference itself to the negative or positive stop completely without an additional signal.
When a referencing method is determined via the object
homing_method
, the following
settings are made:
-
the homing source (neg./pos. limit switch, the homing switch, neg./pos. stop)
-
the direction and process of the homing run
-
the type of evaluation of the zero pulse from the angle encoder used.