6. Setting Parameters
56
Festo P.BE-CMMP-CO-SW-EN 0708NH
6.1.2
Description of the Objects
Object 1011
h
: restore_default_parameters
Index
1011
h
Name
restore_parameters
Object code
ARRAY
No. of Elements 1
Data Type
UINT32
Sub-index
01
h
Description
restore_all_default_parameters
Access
rw
PDO Mapping
no
Units
--
Value Range
64616F6C
h
("load")
Default Value
1 (read access)
The object
1011
h
_ 01
h
(
restore_all_default_parameters
) makes it possible to put the
current parameter set
into a defined state. To achieve this, the
default parameter set
is
copied into the
current parameter set
. The copying process is triggered by a write access
to this object, whereby the string "load" must be transferred as a data record in
hexadecimal form.
This command is only carried out with a deactivated final stage. Otherwise, the SDO error
"Data cannot be transmitted or stored, since the motor controller for this is not in the
correct state" is generated. If the incorrect identifier is sent, the error "Data cannot be
transmitted or stored" is generated. If the object is accessed by reading, a 1 is returned to
show that resetting to default values is supported.
The parameters of the CAN communication (node number, baud rate and operation mode)
as well as numerous angle encoder settings (some of which require a reset to become
effective) remain unchanged.
Object 1010
h
: store_parameters
Index
1010
h
Name
store_parameters
Object code
ARRAY
No. of Elements 1
Data Type
UINT32
Summary of Contents for CMMP Series
Page 2: ......