6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
79
Object 6410
h
_ 03
h
: iit_time_motor
Servo motors may normally be overloaded for a certain time period. This object specifies
how long the current specified in the object
6073
h
(
max_current
) can be applied to the
connected motor. After the IIT time has elapsed, the current is automatically limited to the
value set in the object
6075
h
(
motor_rated_current
) to protect the motor. The standard
setting is two seconds and is valid for most motors.
Index
6410
h
Name
motor_data
Object code
RECORD
No. of Elements 5
Sub-index
03
h
Description
iit_time_motor
Data Type
UINT16
Access
rw
PDO Mapping
no
Units
ms
Value Range
0 … 10000
Default Value
2000
Object 6410
h
_ 04
h
: iit_ratio_motor
With the object
iit_ratio_motor
, the actual capacity utilization of the I
2
t limitation can be
read out in per thousands.
Sub-index
04
h
Description
iit_ratio_motor
Data Type
UINT16
Access
ro
PDO Mapping
no
Units
per thousand
Value Range
--
Default Value
--