6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
119
Object 6510
h
_ 13
h
: homing_switch_selector
The object
6510
h
_ 13
h
(
homing_switch_selector
) establishes whether DIN8 or DIN9
should be used as a homing switch.
Sub-index
13
h
Description
homing_switch_selector
Data Type
INT16
Access
rw
PDO Mapping
no
Units
--
Value Range
0, 1
Default Value
0
Value
Meaning
0
DIN9
1
DIN8
Object 6510
h
_ 15
h
: limit_switch_deceleration
The object
limit_switch_deceleration
establishes the braking deceleration when the limit
switch is reached during normal operation (Limit switch emergency stop ramp).
Sub-index
15
h
Description
limit_switch_deceleration
Data Type
INT32
Access
rw
PDO Mapping
no
Units
acceleration units
Value Range
0 … 3 000 000 min
-1
/s
Default Value
2 000 000 min
-1
/s
6.15
Sampling of positions
6.15.1
Overview
The CMMP family offers the possibility to save the position feedback value on the rising or
falling edge of a digital input. This position value can then be read out, such as for
calculation within a controller.
Summary of Contents for CMMP Series