6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
117
6.14
Limit switch/homing switch
6.14.1
Overview
For the definition of the homing position of the motor controller, either the limit switch or
homing switch can be used. You can find more detailed information on the possible
homing run methods in chapter 8.2, Operating Mode Reference Travel (Homing Mode).
6.14.2
Description of the Objects
Index
Object
Name
Type
Attr.
6510
h
RECORD
drive_data
rw
Object 6510
h
_ 11
h
: limit_switch_polarity
The polarity of the limit switch can be programmed through the object
6510
h
_ 11
h
(
limit_switch_polarity
). A zero is entered in this object for opening limit switches, a one
when closing contacts are used.
Index
6510
h
Name
drive_data
Object code
RECORD
No. of Elements 51
Sub-index
11
h
Description
limit_switch_polarity
Data Type
INT16
Access
rw
PDO Mapping
no
Units
--
Value Range
0, 1
Default Value
1
Value
Meaning
0
Normally closed contact
1
N/O contact