6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
81
Value
Meaning
0
right
1
Left
Object 6410
h
_ 11
h
: encoder_offset_angle
The servo motors used have permanent magnets on the rotor. These generate a magnetic
field, whose orientation toward the stator depends on the rotor position. For electronic
commutation, the motor controller must always set the electromagnetic field of the stator
in the correct angle to this permanent magnet field. To do this, it constantly determines
the rotor position with an angle transmitter (resolver, etc.).
The orientation of the angle transmitter to the permanent magnetic field must be entered
in the object
encoder_offset_angle
. This angle can be determined with the
parameterisation software. The angle determined by the parameterisation software lies
around 180°. It must be calculated as follows:
encoder_offset_angle = "offset angle of the angle encoder"
32767
180°
This object is not changed through
restore_default_parameters
.
Index
6410
h
Name
motor_data
Object code
RECORD
No. of Elements 5
Sub-index
11
h
Description
encoder_offset_angle
Data Type
INT16
Access
rw
PDO Mapping
yes
Units
…
Value Range
-32767 … 32767
Default Value
E000
h
(-45°) (after INIT!)