2. Safety instructions for electrical drives and controllers
14
Festo P.BE-CMMP-CO-SW-EN 0708NH
The motor controller can be protected with an AC/DC-sensitive RCD
circuit breaker (RCD = Residual Current protective Device) of
300 mA.
Warning
For switching the control contacts, gold contacts or contacts with
high contact pressure should be used.
As a precautionary measure, fault-elimination measures for
switching systems must be taken, such as wiring fuses and relays
with RC filters or diodes.
Observe the safety regulations and stipulations of the country in
which the device is used.
Warning
The environmental conditions specified in the product
documentation must be complied with.
Safety-critical applications are not permitted unless expressly
approved by the manufacturer.
The instructions for an EMC-suitable installation should be taken
from the product manual of the CMMP family.
Compliance with the limit values required by the national
regulations is the responsibility of the manufacturer of the system
or machine.
Warning
The technical data, connection and installation requirements for
the motor controller must be taken from this product manual and
must absolutely be complied with.