5. Access Procedure
Festo P.BE-CMMP-CO-SW-EN 0708NH
43
Error_code (hex) Display
Meaning
7383
E 08 3
Error track signals Z1 incremental encoder
7384
E 08 4
Error track signals of digital incremental encoder
7385
E 08 5
Error track signals Hall generator signals incremental encoder
7386
E 08 6
Communication error angle encoder
7387
E 08 7
Signal amplitude incremental track faulty
7388
E 08 8
Internal angle transmitter error
7389
E 08 9
Angle encoder at X2b is not supported
73A1
E 09 0
Type CMMP angle encoder parameter set
73A2
E 09 1
Angle encoder parameter set cannot be decoded
73A3
E 09 2
Angle encoder parameter set: Version unknown
73A4
E 09 3
Angle encoder parameter set: Data structure defective
73A5
E 09 7
EPROM angle encoder write-protected
73A6
E 09 9
EEPROM angle encoder too small
8A80
E 11 0
Homing run: Error at the start
8A81
E 11 1
Error during homing run
8A82
E 11 2
Homing run: Zero pulse error
8A83
E 11 3
Homing run: timeout
8A84
E 11 4
Homing run: Incorrect / invalid limit switch
8A85
E 11 5
Homing run: I
2
t / following error
8A86
E 11 6
Homing run: End of the search section
8180
E 12 0
CAN bus: Double node number
8120
E 12 1
CAN communication error: BUS OFF
8181
E 12 2
Communication error CAN while sending
8182
E 12 3
Communication error CAN while receiving
6185
E 15 0
Division by 0
6186
E 15 1
Outside range (run over/under)
6181
E 16 0
Program execution faulty
6182
E 16 1
Illegal interrupt
6187
E 16 2
Initialisation error
6183
E 16 3
Unexpected state
8611
E 17 x
Limit value contour error exceeded
5280
E 21 1
Error 1 ammeter U
5281
E 21 1
Error 1 ammeter V
5282
E 21 2
Error 2 ammeter U
5283
E 21 3
Error 2 ammeter V
6080
E 25 0
Invalid device type
6081
E 25 1
Device type not supported