![Festo CMMP Series Manual Download Page 93](http://html1.mh-extra.com/html/festo/cmmp-series/cmmp-series_manual_2283112093.webp)
6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
93
Object 6064
h
: position_actual_value
The actual position can be read out via this object. The angle transmitter feeds this to the
position controller. This object is specified in user-defined increments.
Index
6064
h
Name
position_actual_value
Object code
VAR
Data Type
INT32
Access
ro
PDO Mapping
yes
Units
position units
Value Range
--
Default Value
--
Object 6065
h
: following_error_window
The object
following_error_window
(contouring error window) defines a symmetrical
range around the nominal position value (
position_demand_value
). If the position
feedback value (
position_actual_value
) is outside the following error window
(
following_ error_window
), a following error occurs and bit 13 is set in the object
statusword
. The following can cause a following error:
-
the drive is blocked
-
the positioning speed is too high
-
the acceleration values are too large
-
the object
following_error_window
has too small a value
-
the position controller is not correctly parameterised.
Index
6065
h
Name
following_error_window
Object code
VAR
Data Type
UINT32
Access
rw
PDO Mapping
yes
Units
position units
Value Range
--
Default Value
9101 (9101/65536 U = 50°)