![Festo CMMP Series Manual Download Page 96](http://html1.mh-extra.com/html/festo/cmmp-series/cmmp-series_manual_2283112096.webp)
6. Setting Parameters
96
Festo P.BE-CMMP-CO-SW-EN 0708NH
Value
Meaning
0
Limit value following error OFF (Reaction: NO ACTION))
> 0
Limit value following error ON (Reaction: SWITCH OFF FINAL STAGE IMMEDIATELY)
The error 17-0 is activated through a change of the error reaction. The reaction SWITCH
OFF FINAL STAGE IMMEDIATELY is returned as
ON
, all others as
OFF
. When writing with 0,
the error reaction
NO REACTION
is set, when writing with a value greater than 0 the error
reaction SWITCH OFF FINAL STAGE IMMEDIATELY.
See also chapter 6.18, Error management.
Object 607B
h
: position_range_limit
The object group
position_range_limit
contains two subparameters, which limit the
numeric range of the position values. When one of these limits is exceeded, the position
feedback value automatically jumps to the other limit. To be specified are the limits that
should physically equal the same position, for example 0° and 360°.
For these limits to be effective, a round axis mode must be selected via the object
6510
h
_ 20
h
(
position_range_limit_enable
).
Index
607B
h
Name
position_range_limit
Object code
ARRAY
No. of Elements 2
Data Type
INT32
Sub-index
01
h
Description
min_position_range_limit
Access
rw
PDO Mapping
yes
Units
position units
Value Range
..
Default Value
--
Sub-index
02
h
Description
max_position_range_limit
Access
rw
PDO Mapping
yes
Units
position units
Value Range
..
Default Value
..
Summary of Contents for CMMP Series