![Festo CMMP Series Manual Download Page 85](http://html1.mh-extra.com/html/festo/cmmp-series/cmmp-series_manual_2283112085.webp)
6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
85
Index
60F9
h
Name
velocity_control_parameter_set
Object code
RECORD
No. of Elements 3
Sub-index
01
h
Description
velocity_control_gain
Data Type
UINT16
Access
rw
PDO Mapping
no
Units
256 = Gain 1
Value Range
20 … 64 * 256 (16384)
Default Value
256
Sub-index
02
h
Description
velocity_control_time
Data Type
UINT16
Access
rw
PDO Mapping
no
Units
µs
Value Range
1 … 32000
Default Value
2000
Sub-index
04
h
Description
velocity_control_filter_time
Data Type
UINT16
Access
rw
PDO Mapping
no
Units
µs
Value Range
1 … 32000
Default Value
400