6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
75
Object 6510
h
_ 40
h
: nominal_current
The device nominal current can be read out with the object
nominal_current
. It is
simultaneously the upper limit value that can be written into the object
6075
h
(
motor_rated_current
).
Sub-index
40
h
Description
nominal_current
Data Type
UINT32
Access
ro
PDO Mapping
no
Units
mA
Value Range
--
Default Value
device-dependent
Device type
Value
CMMP-AS-C2-3A
2500
CMMP-AS-C5-3A
5000
CMMP-AS-C5-11A-P3
2500
CMMP-AS-C10-11A-P3
5000
Due to the power derating, other values may be displayed,
depending on the controller cycle time and the final stage cycle
frequency.
Object 6510
h
_ 41
h
: peak_current
The device peak current can be read out with the object
peak_current
. It is simultaneously
the upper limit value that can be written into the object
6073
h
(
max_current
).
Sub-index
41
h
Description
peak_current
Data Type
UINT32
Access
ro
PDO Mapping
no
Units
mA
Value Range
--
Default Value
device-dependent