8. Operating modes
Festo P.BE-CMMP-CO-SW-EN 0708NH
187
Object 6069
h
: velocity_sensor_actual_value
With the object
velocity_sensor_actual_value
, the value of a possible speed transmitter
can be read out in internal units. A separate speed transmitter cannot be connected in the
CMMP family. Therefore, to determine the actual speed value, the object
606C
h
should be
used.
Index
6069
h
Name
velocity_sensor_actual_value
Object code
VAR
Data Type
INT32
Access
ro
PDO Mapping
yes
Units
R / 4096 min
Value Range
--
Default Value
--
Object 606A
h
: sensor_selection_code
The speed sensor can be selected with this object. Currently, no separate speed sensor is
planned. Therefore, only the default angle encoder is accessible.
Index
606A
h
Name
sensor_selection_code
Object code
VAR
Data Type
INT16
Access
rw
PDO Mapping
yes
Units
--
Value Range
0
Default Value
0
Object 606B
h
: velocity_demand_value
The current nominal speed of the velocity controller can be read with this object.
It is acted upon by the nominal value of the ramp and curve generators. If the position
controller is activated, its correction speed is also added.
Index
606B
h
Name
velocity_demand_value
Object code
VAR
Data Type
INT32