8. Operating modes
188
Festo P.BE-CMMP-CO-SW-EN 0708NH
Access
ro
PDO Mapping
yes
Units
speed units
Value Range
--
Default Value
--
Object 202E
h
: velocity_demand_sync_value
The command velocity of the synchronisation encoder can be read out via this object.
This is defined by the object
2022
h
synchronization_encoder_select
(see chapter 6.11).
This object is specified in user-defined increments.
Index
202E
h
Name
velocity_demand_sync_value
Object code
VAR
Data Type
INT32
Access
ro
PDO Mapping
no
Units
velocity units
Value Range
--
Default Value
--
Objekt 606C
h
: velocity_actual_value
The actual speed value can be read via the object
velocity_actual_value
.
Index
606C
h
Name
velocity_actual_value
Object code
VAR
Data Type
INT32
Access
ro
PDO Mapping
yes
Units
speed units
Value Range
--
Default Value
--