6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
107
Sub-index
02
h
Description
encoder_emulation_offset
Data Type
INT16
Access
rw
PDO Mapping
no
Units
32767 = 180°
Value Range
-32768 … 32767
Default Value
0
Object 2028
h
: encoder_emulation_resolution
The object encoder_emulation_resolution is present only for compatibility reasons.
It corresponds to the object
201A
h
_ 01
h
.
Index
2028
h
Name
encoder_emulation_resolution
Object code
VAR
Data Type
INT32
Access
rw
PDO Mapping
no
Units
see 201Ah _ 01h
Value Range
see 201Ah _ 01h
Default Value
see 201Ah _ 01h
6.11
Command/feedback value activation
6.11.1
Overview
With the following objects, the source for the command value and the source for the
feedback value can be changed. As standard, the motor controller uses the input for the
motor encoder X2A or X2B as feedback value for the position controller. When an external
positioning encoder is used, e.g. behind a gear, the position value fed in over X10 can be
activated as a feedback value for the position controller. In addition, signals coming in
over X10 (e.g. of a second controller) can be activated as additional command values,
which permits synchronisation operating types.
Summary of Contents for CMMP Series