8. Operating modes
200
Festo P.BE-CMMP-CO-SW-EN 0708NH
Object 6087
h
: torque_slope
This parameter describes the velocity change of the command value ramp. This is
specified in thousandths of the nominal torque per second. For example, the torque-
command value
target_torque
is raised from 0 Nm to the value
motor_rated_torque
.
If the output value of the inserted torque ramp is to reach this value in one second, the
value 1000 must be written in this object.
Index
6087
h
Name
torque_slope
Object code
VAR
Data Type
UINT32
Access
rw
PDO Mapping
yes
Units
motor_rated_torque / 1000 s
Value Range
--
Default Value
E310F94
h
Object 6088
h
: torque_profile_type
The object
torque_profile_type
specifies with which curve shape a command value jump
should be carried out. Currently, only the linear ramp is implemented in this contoller, so
this object can only be written with the value 0.
Index
6088
h
Name
torque_profile_type
Object code
VAR
Data Type
INT16
Access
rw
PDO Mapping
yes
Units
--
Value Range
0
Default Value
0
Value
Meaning
0
Linear ramp