6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
115
Bit
Value
Digital output
0
00000001
h
1 = Apply brake
16 … 23
0E000000
h
Reserved
25 … 27
0E000000
h
DOUT1 … DOUT3
Warning
When brake actuation is enabled via
digital_output_mask
,
the holding brake is manually vented by eletion of bit 0 in
digital_output_data
!
This can result in a sagging of the axis if hanging.
Object 2420
h
: digital_output_state_mapping
Various status messages of the motor controller can be output through the digital outputs
using the object group
digital_outputs_state_mapping
.
For the integrated digital outputs of the motor controller, each output must have its own
subindex. As a result, for each output there is a byte in which the function number must
be entered.
When such a function has been assigned to a digital output and the output is then
switched on or off directly over
digital_outputs
(
60FE
h
), the object
digital_outputs_state_mapping
is also set to OFF (0) or ON (12).
Index
2420
h
Name
digital_outputs_state_mapping
Object code
RECORD
No. of Elements 5
Sub-index
01
h
Description
dig_out_state_mapp_dout_1
Data Type
UINT8
Access
rw
PDO Mapping
no
Units
--
Value Range
0 … 16, see table
Default Value
0