6. Setting Parameters
110
Festo P.BE-CMMP-CO-SW-EN 0708NH
Sub-index
07
h
Description
synchronisation_main
Data Type
UINT16
Access
rw
PDO Mapping
no
Units
--
Value Range
see table
Default Value
--
Bit
Value
Meaning
0
0001
h
0: Synchronization inactive
1: Synchronization active
1
0002
h
"Flying saw" not possible
8
0100
h
0: Synchronization during homing run
1: No synchronisation during homing run
Object 2023
h
: synchronisation_filter_time
The object
synchronisation_filter_time
sets the filter time constant of a PT1 filter, with
which the synchronisation speed is smoothed. This can be necessary especially at low
resolutions, since small changes of the input value already correspond to high speeds.
On the other hand, the drive at high filter times may no longer be able to follow a dynamic
input signal quickly enough.
Index
2023
h
Name
synchronisation_filter_time
Object code
VAR
Data Type
UINT32
Access
rw
PDO Mapping
no
Units
µs
Value Range
10 … 50000
Default Value
600