6. Setting Parameters
108
Festo P.BE-CMMP-CO-SW-EN 0708NH
6.11.2
Description of the Objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
2021
h
VAR
position_encoder_selection
INT16
rw
2022
h
VAR
synchronisation_encoder_selection
INT16
rw
2023
h
VAR
synchronisation_filter_time
UINT32
rw
202F
h
RECORD
synchronisation_selector_data
ro
202F
h
_07
h
VAR
synchronisation_main
UINT16
rw
Object 2021
h
: position_encoder_selection
The object
position_encoder_selection
specifies the encoder input that is used to
determine the actual position (feedback value encoder). This value can be changed to
switch to position control over an external endoder (connected to the drive). Switching is
possible between X10 and the encoder input selected as commutation encoder
(X2A/X2B). If one of the encoder inputs X2A/X2B is selected as position feedback value
encoder, the one used as commutation encoder must be selected. If the other encoder is
selected, switchover to the commutation encoder takes place automatically.
Index
2021
h
Name
position_encoder_selection
Object code
VAR
Data Type
INT16
Access
rw
PDO Mapping
no
Units
--
Value Range
0 … 2 (see table)
Default Value
0
Value
Description
0
X2A
1
X2B
2
X10
Selection is possible only between the encoder input X10 and the
respective commutation encoder X2A or X2B as position feedback
value encoder. It is not possible to use the configuration X2A as
commutation encoder and X2B as position feedback value encoder,
or vice versa.
Summary of Contents for CMMP Series