7
4
Connection
4. Connection
SD3 Series Instruction Manual
2
. Position Control Mode
2. Position Control Mode
1: 24V
24 V
GND
24 V
G24 V
2: G24V
3: COM+
4: SVON
5: RESET
6: HOLD
9: CCWL
10: CWL
11: TLSEL1
12: COM-
13: MBRK
14: SERVO
18: OCZ
19: SRDY+
20: SRDY-
21: ALM+
22: ALM-
26: CMD_PLS
FG
36: OUT_A
37: /OUT_A
38: OUT_B
39: /OUT_B
40: OUT_Z
41: /OUT_Z
43: 485
44: /485
45: SG
42: SG
27: /CMD_PLS
30: CMD_DIR
31: /CMD_DIR
SG
110
Ω
Control power supply 24 V input
Control power supply GND
I/O power supply 24 V input
INPUT
䚷
Servo ON
INPUT
䚷
Alarm reset
INPUT
䚷
Command input
inhibition
INPUT
䚷
CCW run inhibition
INPUT
䚷
CW run inhibition
INPUT
䚷
Torque limit selection
I/O power supply GND
OUTPUT
䚷
Brake release
OUTPUT
ࠉ
Servo state
OUTPUT
䚷
Motion complete
/Under torque limit
㻻㼁㼀㻼㼁㼀䚷㻱㼚㼏㼛㼐㼑㼞㻌㼆㻙㼜㼔㼍㼟㼑
䠄㼛㼜㼑㼚㻙㼏㼛㼘㼘㼑㼏㼠㼛㼞䠅
OUTPUT
䚷
Servo-Ready+
OUTPUT
䚷
Servo-Ready-
OUTPUT
⅙
Alarm State+
OUTPUT
䚷
Alarm State-
Pulse Train
Command Input
A-phase
output
B-phase
output
Z-phase
output
Pulse
RS-422 output
2 m or
shorter
Twisted Pair Cable
Frame
Encoder Signal Output
Direction
Control Power
Shielded
㻖
3
㻖
1
㻖
1
㻖
1
㻖
1
㻖
2
㻖
6
㻖
4
㻖
5
Servo Amplifier
4.7 k
Ω
7: PCLR
INPUT
䚷
Deviation counter
clear
MAX 50 mA
MAX 50 mA
15: POSIN
OUTPUT
ࠉ
Positioning
complete
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
110
Ω
SG
SG
8: HOME
INPUT
䚷
Homing start
16: HEND
OUTPUT
䚷
Homing
complete
MAX 50 mA
17:
MEND/T-LIMIT
RS-485
Host Controller
SG
㻖
5
㻖
4
Pulse Train Command
Differential, I/O Configuration Option 1
CN1 Connector Wiring Example
*1) Control power (24 V, G24 V) and power for I/O (COM+, COM-) must share one common power supply.
*2) When driving a load containing inductance component such as relay, connect a protection circuit (diode).
The motor brake cannot be driven directly. Be sure to use a circuit that interfaces with a diode built-in type relay.
Page 46
PO
Connections to General-Purpose Output Signal
*3) The output circuit configuration is an open collector Darlington transistor output. Connects to relays and optical isolators.
Note that when the transistor is on, connector-emitter voltage V
CE
(SAT) is approximately 1 V; a standard TTL IC does not satisfy V
IL
and cannot be connected directly.
*4) Be sure to connect a termination resistor of approximately 220 Ω .
*5) Make the connection to the communication IC signal ground of the host controller that amplifier encoder output signals are connecting to.
Connecting signal ground SG to control power GND may result in malfunction.
*6) If Z-phase pulse width is too small to be measured accurately by the host controller, decrease pulse division rate by using pulse output
ratio (parameters No.276.0 and No.278,0) or decrease rotational speed to increase the pulse width.
Pulse width [ms] = 2 / rotational speed [r/min] / (division ratio × 2
17
) × 60 × 1,000.
dif.
Summary of Contents for SD3 Series
Page 1: ...R FATEK AUTOMATION CORP Instruction Manual AC SERVO MOTOR and SERVO AMPLIFIER SD3 Series...
Page 6: ...6 MEMO SD3 Series Instruction Manual...
Page 52: ...32 MEMO 2 Specifications SD3 Series Instruction Manual...
Page 92: ...40 MEMO 3 Preparation SD3 Series Instruction Manual...
Page 292: ...48 MEMO SD3 Series Instruction Manual 6 Operation...
Page 338: ...46 MEMO SD3 Series Instruction Manual 7 Tuning...
Page 362: ...24 MEMO 8 Troubleshooting SD3 Series Instruction Manual...
Page 395: ...MEMO SD3 Series Instruction Manual...
Page 396: ...R...