
21
4
Connection
4. Connection
SD3 Series Instruction Manual
3. Velocity Control Mode
3. Velocity Control Mode
1: 24V
24 V
GND
24 V
G24 V
2: G24V
3: COM+
4: SVON
5: RESET
6: VCRUN1
7: VCRUN2
9: VCSEL2
10: VCSEL3
11: TLSEL1
12: COM-
13: MBRK
14: SERVO
8: VCSEL1
17: T-LIMIT
18: OCZ
19: SRDY+
20: SRDY-
21: ALM+
22: ALM-
FG
36: OUT_A
37: /OUT_A
38: OUT_B
39: /OUT_B
40: OUT_Z
41: /OUT_Z
43: 485
44: /485
45: SG
42: SG
SG
Control power supply 24 V input
Control power supply GND
I/O power supply 24 V input
INPUT
䚷
Servo ON
INPUT
䚷
Alarm reset
INPUT
䚷
Start 1 (CCW rotation)
INPUT
䚷
Start 2 (CW rotation)
INPUT
䚷
Internal velocity
command selection 2
INPUT
䚷
Internal velocity
command selection 3
INPUT
䚷
Torque limit selection
I/O power supply GND
OUTPUT
䚷
Brake release
OUTPUT
䚷
Servo state
OUTPUT Under torque
limit
㻻㼁㼀㻼㼁㼀䚷㻱㼚㼏㼛㼐㼑㼞㻌㼆㻙㼜㼔㼍㼟㼑
䠄
open-collector
䠅
OUTPUT
䚷
Servo-Ready+
OUTPUT
䚷
Servo-Ready-
OUTPUT
䚷
Alarm State+
OUTPUT
䚷
Alarm State-
㻌㻌
A-phase
output
B-phase
output
Z-phase
output
RS-422 output
Twisted Pair Cable
Frame
Encoder Signal Output
Control Power
Shielded
㻖
3
㻖
1
㻖
1
㻖
1
㻖
1
㻖
2
㻖
6
㻖㻠
㻖
5
Servo Amplifier
4.7 k
Ω
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
SG
SG
INPUT
䚷
Internal velocity
command selection 1
RS-485
Host Controller
SG
㻖
5
㻖
4
Internal Velocity Command
CN1 Connector Wiring Example
*1) Control power (24 V, G24 V) and power for I/O (COM+, COM-) must share one common power supply.
*2) When driving a load containing inductance component such as relay, connect a protection circuit (diode).
The motor brake cannot be driven directly. Be sure to use a circuit that interfaces with a diode built-in type relay.
Page 46
PO
Connections to General-Purpose Output Signal
*3) The output circuit configuration is an open collector Darlington transistor output. Connects to relays and optical isolators.
Note that when the transistor is on, connector-emitter voltage V
CE
(SAT) is approximately 1 V; a standard TTL IC does not satisfy V
IL
and cannot be connected directly.
*4) Be sure to connect a termination resistor of approximately 220 Ω .
*5) Make the connection to the communication IC signal ground of the host controller that amplifier encoder output signals are connecting to.
Connecting signal ground SG to control power GND may result in malfunction.
*6) If Z-phase pulse width is too small to be measured accurately by the host controller, decrease pulse division rate by using pulse output
ratio (parameters No.276.0 and No.278,0) or decrease rotational speed to increase the pulse width.
Pulse width [ms] = 2 / rotational speed [r/min] / (division ratio × 2
17
) × 60 × 1,000.
i/o
䐟
䐠
䐡
Summary of Contents for SD3 Series
Page 1: ...R FATEK AUTOMATION CORP Instruction Manual AC SERVO MOTOR and SERVO AMPLIFIER SD3 Series...
Page 6: ...6 MEMO SD3 Series Instruction Manual...
Page 52: ...32 MEMO 2 Specifications SD3 Series Instruction Manual...
Page 92: ...40 MEMO 3 Preparation SD3 Series Instruction Manual...
Page 292: ...48 MEMO SD3 Series Instruction Manual 6 Operation...
Page 338: ...46 MEMO SD3 Series Instruction Manual 7 Tuning...
Page 362: ...24 MEMO 8 Troubleshooting SD3 Series Instruction Manual...
Page 395: ...MEMO SD3 Series Instruction Manual...
Page 396: ...R...