Problem 2. Servomotor not turning ON
Cause
Remedy
The servo on signal (SVON)
is not being input.
Input the SVON signal of the host connector to the user I/O connector.
The primary circuit power is not
supplied.
(Alarm No.15 is displayed)
Verify that CHARGE LED is on.
If it is off, verify that the primary circuit power is not loose, and the primary
circuit power is output.
The motor power connector
is loose.
Connect the user I/O connector firmly.
The amplifier is faulty.
Please contact our distributor.
The Setup Panel shows, but the servo cannot be turned on.