SD3 Series Instruction Manual
7. Tuning
3. Tuning Parameters
Function
Increasing this parameter value will reduce the position deviation after the command
becomes zero� Increase when the convergence of the position deviation at settling is not
good�
Parameter
No.115.0
Default:
50 rad/s
Setting range:
5 to 1,000
Remark
Select a value no higher than
Position Control Mode: Control Gain 2
(No�116�0)�
Set a value smaller than the value of
Control Gain 2
(No�116�0)�
Making a change to any of the following will also change other tuning parameters
(such as Control Gain 2) to the prearranged parameter set all at once�
•
Control Gain Set
(No�113�0)
•
Inertia conditions
(No�113�1)
•
Control Level
(No�114�0)
Tuning Tip
Increasing this parameter setting will improve the settling time in cases when increasing
the control gain set or control level does not resolve poor convergence of position
deviation, or noise is too much that the control gain set or control level should not be
increased�
Differences in Position Deviation Convergence
Position Control Mode: Control Gain 1
High
Low
Velocity command value
Position deviation
Summary of Contents for SD3 Series
Page 1: ...R FATEK AUTOMATION CORP Instruction Manual AC SERVO MOTOR and SERVO AMPLIFIER SD3 Series...
Page 6: ...6 MEMO SD3 Series Instruction Manual...
Page 52: ...32 MEMO 2 Specifications SD3 Series Instruction Manual...
Page 92: ...40 MEMO 3 Preparation SD3 Series Instruction Manual...
Page 292: ...48 MEMO SD3 Series Instruction Manual 6 Operation...
Page 338: ...46 MEMO SD3 Series Instruction Manual 7 Tuning...
Page 362: ...24 MEMO 8 Troubleshooting SD3 Series Instruction Manual...
Page 395: ...MEMO SD3 Series Instruction Manual...
Page 396: ...R...