4
・
・
・
x3
SD3 Series Instruction Manual
6. Operation
1. Configuring Operation Mode
2. Configuring Parameters
Using the Setup Panel
When you finish with the change, the blink turns solid.
Change the parameter value.
Control Mode
Use
to change the number of the parameter.
While you are editing the value, the position that you
selected blinks.
Change Set
After editing parameter
values, proceed with
Parameter Saving Mode.
Command Mode
Settings
0
: Position control mode
1
: Velocity control mode
2
: Torque control mode
Change Set
Settings
1
: Pulse train command
2
: Analog command
3
: Internal command
Save the parameter settings in Parameter Saving mode to the amplifier.
If you shut down the amplifier without saving them, the changes will not
take effect.
Repeat these Steps for each parameter that you select.
Example:
Change the settings of Control Mode and Command Mode to "position control
mode" and "internal command" respectively.
Parameter Setting Mode
Parameter Saving Mode
Normal End
Abnormal End
Saving
Check in Alarm Display Mode.
MODE x 3
(Press three times)
or
Approx.
5 sec
Summary of Contents for SD3 Series
Page 1: ...R FATEK AUTOMATION CORP Instruction Manual AC SERVO MOTOR and SERVO AMPLIFIER SD3 Series...
Page 6: ...6 MEMO SD3 Series Instruction Manual...
Page 52: ...32 MEMO 2 Specifications SD3 Series Instruction Manual...
Page 92: ...40 MEMO 3 Preparation SD3 Series Instruction Manual...
Page 292: ...48 MEMO SD3 Series Instruction Manual 6 Operation...
Page 338: ...46 MEMO SD3 Series Instruction Manual 7 Tuning...
Page 362: ...24 MEMO 8 Troubleshooting SD3 Series Instruction Manual...
Page 395: ...MEMO SD3 Series Instruction Manual...
Page 396: ...R...