45
SD3 Series Instruction Manual
Tuning
7
7. Tuning
4. Using "Servo Studio" to Measure Vibration Frequency (FFT)
4. Using "Servo Studio" to Measure Vibration Frequency (FFT)
8
Click on the icon for the filter that you want to set�
Up to four levels of the position command filters are and
three levels of torque command filters are available�
9
Set the filter parameters�
For the notch filer, enter the vibration frequency measured�
10
Click on
Waveform
monitor
to return to the waveform monitor�
8
9
10
6HUYR6WXGLR
The filter that you just set will be shown on the list�
11
Unchecking the check box will switch ON/OFF of the filer�
Switch on to verify the filter effect� Switching off will not
lose the filter parameter�
11
6HUYR6WXGLR
Tip for Notch Filter Setup
When you are setting a notch filter, use the initial value for the notch width and check the effect first�
After setting the notch filer, start the equipment, verify the filter effect, and lower the notch frequency gradually�
Measure the waveforms to find the best filter conditions such as frequency, width, and depth�
The notch frequency varies depending on the equipment�
Summary of Contents for SD3 Series
Page 1: ...R FATEK AUTOMATION CORP Instruction Manual AC SERVO MOTOR and SERVO AMPLIFIER SD3 Series...
Page 6: ...6 MEMO SD3 Series Instruction Manual...
Page 52: ...32 MEMO 2 Specifications SD3 Series Instruction Manual...
Page 92: ...40 MEMO 3 Preparation SD3 Series Instruction Manual...
Page 292: ...48 MEMO SD3 Series Instruction Manual 6 Operation...
Page 338: ...46 MEMO SD3 Series Instruction Manual 7 Tuning...
Page 362: ...24 MEMO 8 Troubleshooting SD3 Series Instruction Manual...
Page 395: ...MEMO SD3 Series Instruction Manual...
Page 396: ...R...