6. Operation
5. Position Control Mode
5. Position Control Mode
Homing with "Servo Studio"
1. Parameter Tab
Setting homing parameters
2. Point Table Tab
Click Servo ON
(Have the motor in a Servo-ON state)
3. Click Start to start homing
・Click Pause to pause homing.
・When homing is completed, the indicator to the left of
the Start button will turn green and the Current position
cell will show the current position resulting from homing.
Start
Stop
6HUYR6WXGLR
Required Parameters
Name
Setting
Parameter No.
Control Mode
0: Position Control Mode
2.0
Command Mode
3: Internal Command Mode
3.0
Operation Mode
(*)
0: I/O input
1: Communication ("Servo Studio") input
9.0
Internal Position
Operation Mode
0: Point Table
642.0
Set the operation mode.
*)Operation Mode (No. 9.0) = 0 (I/O) upon amplifier power on.