create cfm md
<string 22> {md_index <uint 1-4294967295>} level <int 0-7>
●
config cfm md
[<string 22> | md_index <uint 1-4294967295>] {mip [none | auto |
explicit] | sender_id [none | chassis | manage | chassis_manage]}
●
create cfm ma
<string 22> {ma_index <uint 1-4294967295>} md [<string 22> |
md_index <uint 1-4294967295>]
●
config cfm ma
[<string 22> | ma_index <uint 1-4294967295>] md [<string 22> |
md_index <uint 1-4294967295>] {vlanid <vlanid 1-4094> | mip [none | auto |
explicit | defer] | sender_id [none | chassis | manage | chassis_manage | defer]
| ccm_interval [10ms | 100ms | 1sec | 10sec | 1min | 10min] | mepid_list [add |
delete] <mepid_list>}
●
create cfm mep
<string 32> mepid <int 1-8191> md [<string 22> | md_index <uint 1-
4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>] direction [inward |
outward] port <port>
●
config cfm mep
[mepname <string 32> | mepid <int 1-8191> md [<string 22> |
md_index <uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]]
{state [enable | disable] | ccm [enable | disable] | pdu_priority <int 0-7> |
fault_alarm [all | mac_status | remote_ccm | error_ccm | xcon_ccm | none] |
alarm_time <centisecond 250 -1000> | alarm_reset_time <centisecond 250-1000>}
●
delete cfm mep
[mepname <string 32> | mepid <int 1-8191> md [<string 22> |
md_index <uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]]
●
delete cfm ma
[<string 22> | ma_index <uint 1-4294967295>] md [<string 22> |
md_index <uint 1-4294967295>]
●
delete cfm md
[<string 22> | md_index <uint 1-4294967295>]
●
enable cfm
●
disable cfm
●
config cfm ports
<portlist> state [enable | disable]
●
show cfm ports
<portlist>
●
show cfm
{[md [<string 22> | md_index <uint 1-4294967295>] {ma [<string 22> |
ma_index <uint 1-4294967295>] {mepid <int 1-8191>}} | mepname <string 32>]}
●
show cfm fault
{md [<string 22> | md_index <uint 1-4294967295>] {ma [<string 22>
| ma_index <uint 1-4294967295>]}}
●
show cfm port
<port> {level <int 0-7> | direction [inward | outward] | vlanid
<vlanid 1-4094>}
●
cfm loopback
<macaddr> [mepname <string 32> | mepid <int 1-8191> md [<string 22>
| md_index <uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]]
{num <int 1-65535> | [length <int 0-1500> | pattern <string 1500>] | pdu_priority
<int 0-7>}
Summary of Contents for EAS 200-24p Switch
Page 18: ...Table of Contents Extreme Networks EAS 200 24p Switch CLI Manual 18...
Page 26: ...Chapter 1 Using the Command Line Interface Extreme Networks EAS 200 24p Switch CLI Manual 26...
Page 48: ...Chapter 2 Basic Command List Extreme Networks EAS 200 24p Switch CLI Manual 48...
Page 72: ...Chapter 3 802 1Q VLAN Command List Extreme Networks EAS 200 24p Switch CLI Manual 72...
Page 250: ...Chapter 13 Cable Diagnostics Command List Extreme Networks EAS 200 24p Switch CLI Manual 250...
Page 330: ...Chapter 19 Debug Software Command List Extreme Networks EAS 200 24p Switch CLI Manual 330...
Page 344: ...Chapter 21 DHCP Relay Command List Extreme Networks EAS 200 24p Switch CLI Manual 344...
Page 358: ...Chapter 22 Filter Database FDB Command List Extreme Networks EAS 200 24p Switch CLI Manual 358...
Page 442: ...Chapter 25 IGMP MLD Snooping Command List Extreme Networks EAS 200 24p Switch CLI Manual 442...
Page 466: ...Chapter 29 Link Aggregation Command List Extreme Networks EAS 200 24p Switch CLI Manual 466...
Page 532: ...Chapter 34 Mirror Command List Extreme Networks EAS 200 24p Switch CLI Manual 532...
Page 598: ...Chapter 40 OAM Commands Extreme Networks EAS 200 24p Switch CLI Manual 598...
Page 604: ...Chapter 41 Peripherals Command List Extreme Networks EAS 200 24p Switch CLI Manual 604...
Page 608: ...Chapter 42 Ping Command List Extreme Networks EAS 200 24p Switch CLI Manual 608...
Page 620: ...Chapter 43 Port Security Command List Extreme Networks EAS 200 24p Switch CLI Manual 620...
Page 632: ...Chapter 45 Power Saving Command List Extreme Networks EAS 200 24p Switch CLI Manual 632...
Page 654: ...Chapter 47 QinQ Command List Extreme Networks EAS 200 24p Switch CLI Manual 654...
Page 692: ...Chapter 49 Secure Shell SSH Command List Extreme Networks EAS 200 24p Switch CLI Manual 692...
Page 733: ...upload tech_support_toTFTP Extreme Networks EAS 200 24p Switch CLI Manual 733...
Page 802: ...Chapter 56 System Log Command List Extreme Networks EAS 200 24p Switch CLI Manual 802...
Page 806: ...Chapter 57 System Severity Command List Extreme Networks EAS 200 24p Switch CLI Manual 806...
Page 844: ...Chapter 64 Trusted Host Command List Extreme Networks EAS 200 24p Switch CLI Manual 844...
Page 850: ...Chapter 65 Unicast Routing Command List Extreme Networks EAS 200 24p Switch CLI Manual 850...
Page 906: ...Appendix A System Log Entries Extreme Networks EAS 200 24p Switch CLI Manual 906...