Installation 3. Power-ON
36
RC700-D Rev.2
3.2 Power ON Procedure
(1)
Check the M/C power cable connection.
(2)
Check the M/C signal cable connection.
(3)
Check the EMERGENCY connector connection.
(4)
Connect the TP bypass plug to the TP port of the Robot Controller.
(5)
Connect the AC power cable to the power supply socket.
(6)
Turn ON the POWER switch of the Controller.
(7)
The seven-segment LED blinks as
approximately 30 seconds after
Controller starts up normally.
If an error is displayed, check connection in step (1) to (5) and turn ON the power
again.
If an error is displayed after checking the connection, contact the supplier in your
region.