ip address
SecureStack C3 Configuration Guide
19-5
ip address
Use
this
command
to
set,
remove,
or
disable
a
primary
or
secondary
IP
address
for
an
interface.
The
no
form
of
this
command
removes
the
specified
IP
address
and
disables
the
interface
for
IP
processing.
Syntax
ip address ip-address ip-mask
[
secondary]
no ip address
ip-address ip-mask
Parameters
Defaults
If
secondary
is
not
specified,
the
configured
address
will
be
the
primary
address
for
the
interface.
Mode
Router
interface
configuration:
C3(su)
‐
>router(Config
‐
if(Vlan
1
))#
Usage
Each
SecureStack
C3
system
supports
up
to
24
routing
interfaces,
with
up
to
8
secondary
addresses
allowed
for
each
primary
IP
address.
Table 19-1
show ip interface Output Details
Output Field
What It Displays...
Vlan
N
Whether the interface is administratively and operationally up or down.
Primary IP Address
Inteface’s primary IP address and mask. Set using the
ip address
command as
described in “
ip address
” on page 19-5.
Frame Type
Encapsulation type used by this interface. Set using the
arp
command as described
in “
arp
” on page 19-13.
MAC-Address
MAC address mapped to this interface.
Incoming Access
List
Whether or not an access control list (ACL) has been configured for ingress on this
interface using the commands described in “
Configuring Access Lists
” on
page 26-79.
Outgoing Access
List
Not supported.
MTU
Interface’s Maximum Transmission Unit size.
ARP Timeout
Duration for entries to stay in the ARP table before expiring. Set using the
arp
timeout
command as described in “
arp timeout
” on page 19-15.
Direct Broadcast
Whether or not IP directed broadcast is enabled. Set using the ip directed-broadcast
command described in “
ip directed-broadcast
” on page 19-16.
Proxy Arp
Whether or not proxy ARP is enabled or disabled for this interface. Set using the
ip
proxy arp
command as described in “
ip proxy-arp
” on page 19-14.
ip
‐
address
Specifies
the
IP
address
of
the
interface
to
be
added
or
removed.
ip
‐
mask
Specifies
the
mask
for
the
associated
IP
subnet.
secondary
(Optional)
Specifies
that
the
configured
IP
address
is
a
secondary
address.
Summary of Contents for SECURESTACK C3
Page 2: ......
Page 34: ...xxxii...
Page 40: ...Getting Help xxxviii About This Guide...
Page 126: ...clear license 4 6 Activating Licensed Features...
Page 132: ...set port inlinepower 5 6 Configuring System Power and PoE...
Page 228: ...clear port protected name 7 60 Port Configuration...
Page 270: ...clear snmp interface 8 42 SNMP Configuration...
Page 396: ...clear port txq 12 10 Port Priority Configuration...
Page 414: ...ip igmp robustness 13 18 IGMP Configuration...
Page 542: ...clear arpinspection statistics 17 32 DHCP Snooping and Dynamic ARP Inspection...
Page 546: ...Enabling Router Configuration Modes 18 4 Preparing for Router Mode...
Page 640: ...traceroute ipv6 21 10 IPv6 Management...
Page 698: ...show ipv6 dhcp binding 24 20 DHCPv6 Configuration...
Page 746: ...show ipv6 ospf virtual link 25 48 OSPFv3 Configuration...
Page 834: ...ip access group 26 88 Authentication and Authorization Configuration...
Page 848: ...TACACS Configuration clear tacacs interface 27 14...
Page 866: ...sFlow Configuration show sflow agent 28 18...
Page 872: ...Index 4...