Dialler Options 2
LOCATION 225
0
Option
Description
1
Send Open/Close Reports Only If A Previous Alarm Has Occurred
2
Reserved
4
Send Open/Close Reports When In STAY Mode
8
Delay Siren Until Transmission Complete
Table 80: Dialler Options 2
Send Open/Close Reports Only If A Previous Alarm Has Occurred
This option requires Open/Close reports in “LOCATION 180 - 181” to be enabled on page 113
for it to be effective.
An opening report will be transmitted to the base station receiver when the system has been
disarmed after an alarm has occurred. When the system has been armed, a closing report will
be transmitted. An opening or closing report will not report again until the system has
registered another alarm condition.
If the system is disarmed when an alarm occurs, only a closing report will be transmitted
when the system is next armed.
Reserved
Send Open/Close Reports When In STAY Mode
If open and close reports (Contact ID Event Code 401) are required when the system is armed
in STAY Mode, this option will need to be selected.
This option requires Open/Close reports in “LOCATION 180 - 181” to be enabled on page 113
for it to be effective.
Delay Siren Until Transmission Complete
If this option has been selected, the horn speaker, bell and strobe outputs will not activate until
the base station receiver has sent a kiss-off back to the control panel after the message has been
transmitted. If multiple messages are transmitted, the sirens will activate after the last kiss-off
has been sent.
1
22
4
8
System and Consumer Options
135
Electronics Design and Manufacturing Pty Limited
ISSUE123.DOC
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......