Codepad Duress Alarm
A codepad duress alarm can be used as a hold up alarm. This will occur when the number
9
is added to the end of any valid user code that is being used to disarm the system. A duress
alarm is always silent and can only be made use of if your system is reporting back to a
monitoring station or pocket pager. If you wish to disable the reporting of the codepad duress
alarm report, refer to “LOCATION 156 - 159” on page 109 for more information.
+
9
+
Codepad Panic Alarm - Versions Up To 1.26
A panic alarm will occur when any two outside buttons in the same horizontal row on a
codepad are pressed simultaneously. This is an audible alarm. Refer to Option 4 in
"LOCATION 227" on page 137 to enable codepad panic to be silent. If you wish to disable the
reporting of the codepad panic alarm report, refer to “LOCATION 160 - 163” on page 110 for
more information.
1
+
3
or
4
+
6
or
7
+
9
or
+
Codepad Panic Alarm – Version 1.27 Onwards
A codepad panic alarm will be triggered when either the
1
and
3
buttons or the
and
buttons are pressed simultaneously. This is an audible alarm. Refer to Option 4 in
"LOCATION 227" on page 137 to enable codepad panic to be silent. If you wish to disable the
reporting of the codepad panic alarm report, refer to “LOCATION 160 - 163” on page 110 for
more information.
1
+
3
or
+
Codepad Fire Alarm – Version 1.27 Onwards
A codepad fire alarm will be triggered when the
4
and
6
buttons on the remote codepad are
pressed simultaneously. A distinct fire sound is emitted through the horn speaker to indicate
this type of alarm condition. The fire sound is different to the burglary sound. This is an
audible alarm.
4
+
6
Codepad Medical Alarm – Version 1.27 Onwards
A codepad medical alarm will be triggered when the
7
and
9
buttons on the codepad are
pressed simultaneously. This is an audible alarm.
7
+
9
To disable both the reporting and the audible alarms for codepad panic, codepad fire and
codepad medical alarms, the dialler channel for “Codepad Panic” in “LOCATION 163” on
page 110 should be set as zero and enable Option 4 in “LOCATION 227” on page 137.
Codepad fire and codepad medical alarms can not be disabled without disabling
codepad panic alarms.
40
Solution 4+4
Installation Manual
ISSUE123.DOC
Electronics Design and Manufacturing Pty Limited
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......