Zone Programming
Each zone contains eight locations which are divided into two groups of four. The first four
locations determine how the zone operates, while the second four locations contain the dialler
reporting information.
Zone Operating Information
Zone Type
This location programs the “Zone Type” required (eg. Delay-1,
Instant, 24 Hour etc).
Zone Option
This location controls the zone (eg. Lockout Siren, Silent etc).
Zone Pulse Count
This location sets how many times the zone must trigger within the
time specified in the “Zone Pulse Count Time.
Zone Pulse Count Time
This parameter sets the time period for the number of times the zone
must trigger before activating an alarm.
Zone Reporting Information
Hundreds Digit
The hundreds digit of the Contact ID Event Code is programmed into
this location. This location is also the “Alarm Restore” code in all
other reporting formats.
Tens Digit
The tens digit of the Contact ID Event Code is programmed into this
location. This location is the “Alarm” code in all other reporting
formats.
Units Digit
The units digit of the Contact ID Event Code is programmed into this
location. This location is the “Channel” code that the zone reports on
in other reporting formats other than Contact ID Format.
Dialler Channel
This location is factory default to report on dialler channel 1. If the
system has been partitioned, zones allocated to report on areas other
than Area 1 should have their dialler channel correspond to the area
number that the zone is allocated to.
98
Solution 4+4
Installation Manual
ISSUE123.DOC
Electronics Design and Manufacturing Pty Limited
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......