Test Reporting Time
LOCATION 182 - 185
00 0 9
(Hour)
(Repeat)
(Exp)
Location
Description
182
Actual Hour Of The Day (Tens Digit)
183
Actual Hour Of The Day (Units Digit)
184
Repeat Interval In Days (0 – 15)
185
Expansion Code For 4+2 Format
Table 63: Test Reporting Time Locations
A "Test" report (Contact ID Event Code 602) is a specific signal that is transmitted to the base
station receiver and is normally used to test the dialling and reporting functions of the control
panel. Test reports will not report if the Subscriber ID Number is 0000.
When programming test reports, the control panel needs to know the hour as well as how often
to transmit the report. Test reports are reported on a daily basis ranging from every day to
every fifteen days. Refer to "Installer Code Functions" on page 46 to set the first test report.
If you do not require "Test" reports, program the repeat interval in "LOCATION 182 - 185"
as zero.