System Time
LOCATION 901 – 904
0000
Location
Description
901
Current Hour In 24 Hour Time (Tens Digit)
902
Current Hour In 24 Hour Time (Units Digit)
903
Current Minute (Tens Digit)
904
Current Minute (Units Digit)
Table 78: System Time Locations
The
Solution 4+4
control panel has a real time 24 hour clock that needs to be set during
installation. This time must be set in 24 hour format (ie. 10:30 PM would be programmed as
2230). Every time the system has been powered down, the system time will need to be reset.
Setting The Date and Time
The Master Code holder is allowed to set the date and time as follows:
How To Set The New Date and Time
1.
Enter your
followed by
6
and the
button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
2.
Enter the day, month, year, hour and minute using the (DD, MM, YY, HH, MM)
format.
3.
Press the
button when finished.
Two beeps will be heard and the
STAY
and
AWAY
indicators will extinguish.
+
6
+
Example
If the date and time needs to be set for the 1st January 1997 at 10:30 PM, program the date and
time as follows;
+
6
+
0
+
1
+
0
+
1
+
9
+
7
+
2
+
2
+
3
+
0
+
132
Solution 4+4
Installation Manual
ISSUE123.DOC
Electronics Design and Manufacturing Pty Limited
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......