16
Horn Speaker Monitor Fail
If Option 4 – Enable Monitoring Of Horn Speaker in "LOCATION 226" on page
136 has been selected, this output will operate when the horn speaker has been
disconnected. The output will reset when the horn speaker has been reconnected.
17
Sensor Watch Alarm
This output will operate when the sensor watch count has been reached. Refer to
"Zone Options" on page 102 for more information on programming zones for sensor
watch. Refer to "LOCATION 218 - 219" on page 129 for setting how many days
before a zone can register as a faulty sensor watch zone.
18
Codepad Medical Alarm (New – Software Version 1.27)
This output will operate when a codepad medical alarm has been activated by
pressing the
7
and
9
buttons on the remote codepad simultaneously. This output
will reset once a valid user code has been entered at the remote codepad.
19
Codepad Fire Alarm (New – Software Version 1.27)
This output will operate when a codepad fire alarm has been activated by pressing
the
4
and
6
buttons on the remote codepad simultaneously. This output will reset
once a valid user code has been entered at the remote codepad.
1
Codepad Panic Alarm
This output will operate when a codepad panic alarm (audible or silent) has been
activated by pressing the
1
and
3
buttons or the
and
buttons on the
remote codepad simultaneously. This output will reset once a valid user code has
been entered at the remote codepad.
1
Codepad Duress Alarm
This output will operate when a duress alarm has been activated by adding a
9
to
the end of the user code being used to disarm the system. This output will reset the
next time the system has been armed.
1
Codepad Tamper
This output will operate when the wrong code has been entered more times than
allowed. Refer to "LOCATION 102" on page 92 for setting the number of incorrect
attempts that may be allowed. This output will reset once a valid user code has been
entered.
1
Speaker Beeps
This output will function during all remote radio/keyswitch operations allowing you
to fit a 12V DC buzzer or light to provide status indication for the system operator.
Option 8 – Enable Horn Speaker Beeps For Remote Control Operation in
"LOCATION 226" on page 136 is not required to be selected for this event type to
operate.
No Of Beeps
System Status
1
System Disarmed
2
System Armed In AWAY Mode
3
System Armed In STAY Mode
Table 64: Horn Speaker Beeps
1
Sirens Running
This output will operate for the duration of the siren run time programmed in
"LOCATION 221" on page 130. When the sirens have been activated, this output
will reset once the siren run time has expired.
20
Strobe Operating
This output will operate when an alarm condition occurs and will reset once a valid
user code has been entered.
120
Solution 4+4
Installation Manual
ISSUE123.DOC
Electronics Design and Manufacturing Pty Limited
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......