Consumer Options 1
LOCATION 229
2
Option
Description
1
Send Test Reports Only If The System Is Armed
2
Enable Operation Of Siren and Strobe In STAY Mode
4
Enable Answering Machine Bypass Only When Armed
8
Enable Codepad Extinguish Mode
Table 85: System Options 4
Send Test Reports Only If The System Is Armed
If this option has been selected, test reports (Contact ID Event Code 602) will only be sent
when the system has been armed in AWAY Mode or STAY Mode. It is no longer necessary to
send a test report as well as an opening and closing report every day.
During the working week, most commercial premises would be open and therefore a test report
is not necessary, as open and close reports would be sent at the time programmed.
Refer to “Test Reporting Time” on page 114 to set the test report time required.
Enable Operation Of Siren & Strobe In STAY Mode
This option will need to be selected if audible alarms are required when the system has been
armed in STAY Mode.
Enable Answering Machine Bypass Only When Armed
This option needs to be selected if the answering machine bypass feature is required to operate
only when the system has been armed. When the system is disarmed, the control panel will not
answer any incoming calls. This option is beneficial in high telephone traffic installations
where the control panel could answer an incoming call. Refer to “LOCATION 060” on page
87 to enable answering machine bypass.
Enable Codepad Extinguish Mode
If this option has been selected, all indicators on the remote codepads will extinguish if a
button is not pressed for 60 seconds. The indicators will illuminate when there is an alarm
(except a silent alarm), when a button is pressed on the codepad, when the AC mains fail
beeps, or if the entry timer has been activated.
1
8
4
2
System and Consumer Options
139
Electronics Design and Manufacturing Pty Limited
ISSUE123.DOC
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......