Arming The System In STAY Mode
STAY Mode is when the system has been armed with particular zones automatically isolated.
Refer to “Zone Options” on page 102 for further information.
When there is a need to arm only the system perimeter, this mode is extremely handy. It
automatically disables the interior detection zones allowing movement within the protected
area while at the same time arming the perimeter zones.
There are two methods for arming your system in STAY Mode. Method one is standard and
will always operate. Method two is optional and needs to be enabled in "LOCATION 230” on
page 140.
Single button arming in STAY Mode will report as user code number 32.
Method One
How To Arm The System In STAY Mode
1.
Enter your
followed by the
button.
Two beeps will be heard and the
STAY
indicator will illuminate. Exit time will now
commence.
Any zones that have been programmed for STAY Mode will be automatically isolated
and their respective indicators will begin to flash until exit time expires. At the end of
exit time, the
ZONE
indicators will extinguish and the codepad will give one short beep.
+
Method Two
How To Arm The System In STAY Mode
1.
Hold down the
button until two beeps are heard.
The
STAY
indicator will illuminate and exit time will now commence.
Any zones that have been programmed for STAY Mode will be automatically isolated
and their respective indicators will begin to flash until exit time expires. At the end of
exit time, the
ZONE
indicators will extinguish and the codepad will give one short beep.
If a zone is not sealed at the end of exit time, the zone will be automatically isolated. The zone
will become an active part of the system again as soon as it has resealed (ie. If a window is left
open after exit time has expired, the window will not be an active part of the system until it has
closed. Opening the window after exit time has expired will cause an alarm condition).
Forced Arming
The feature of arming the system when a zone is not sealed is known as forced arming. Refer
to Option 1 in “LOCATION 226” on page 136 for more information on forced arming.
If the
STAY
indicator does not illuminate and a long beep is heard when attempting to arm the
system, forced arming is not permitted. If this is the case, you must ensure that all zones are
sealed or manually isolated before you can arm the system.
38
Solution 4+4
Installation Manual
ISSUE123.DOC
Electronics Design and Manufacturing Pty Limited
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......