Isolating Zones
When a zone has been isolated, access is allowed into that zone at all times. Isolating zones is
performed by one of two methods. One way requires the use of a valid user code while the
other way does not. The ability to isolate zones is governed by the priority level allocated to
each user code holder. Some user code holders may not be able to isolate zones. Refer to
"User Code Priority" on page 91 for further information.
Twenty four hour zone types and zone not used cannot be isolated. If isolation of these zones
is attempted, a long beep will be heard.
Standard Isolating
1.
Press the
button twice.
Three beeps will be heard.
2.
* Enter the
required to be isolated followed by the
button.
The zone you just selected to be isolated will now begin to flash.
Repeat Step 2 if more than one zone is required to be isolated until all zones that are
required to be isolated have been selected.
3.
Press the
button when finished selecting the zones to be isolated.
Two beeps will be heard.
The isolated zones will now continue to flash until the system has next been disarmed. The
system is ready to be armed in AWAY Mode.
+
+
+
+
+
+
*
As each zone is isolated, the corresponding ZONE indicator will begin to flash. If a
mistake is made, press the zone number that was incorrectly entered followed by the
button. This zone is now no longer isolated and the ZONE indicator will
extinguish.
System Indicators and Operations
41
Electronics Design and Manufacturing Pty Limited
ISSUE123.DOC
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......