Codepad Lockout Time
LOCATION 220
0
Location
Description
220
Increments Of 10 Seconds
Table 74: Codepad Lockout Time Locations
All codepads will be locked out for the specified time programmed if an invalid code has been
entered more times than allowed by the code retry attempts programmed in "LOCATION 102"
on page 92. If the "Codepad Lockout Time" is programmed as zero, no codepad lockout will
occur.
Siren Run Time
LOCATION 221
(Defaulted To 10 Minutes)
Location
Description
221
Increments Of 1 Minute (0 – 15)
Table 75: Siren Run Time Locations
The siren run time determines how long the horn speaker will activate during an alarm
condition. The siren run time can be programmed between 0-15 minutes (+/- 1 minute).
Siren Sound Rate
LOCATION 222
7
Location
Description
222
Siren Sound Rate (0 = SLOWEST 15 = FASTEST)
Table 76: Siren Sound Rate Locations
The siren sound rate varies the frequency of the siren tone. Zero rate is the slowest and fifteen
is the fastest rate. The siren sound rate does not change the frequency rate for the fire alarm
tone.