Swinger Shutdown Count
LOCATION 223
0
Location
Description
223
Swinger Shutdown Count (0-15)
Table 77: Swinger Shutdown Count
This location determines the number of times the sirens and dialler can be triggered before any
lockout options will take effect. A minimum of one zone must be programmed for lockout
siren or dialler for this location to be effective. Refer to “Zone Options” on page 102 for more
information on programming zones for lockout siren or lockout dialler.
Only alarms triggered from zone inputs will increment the swinger shutdown counter. This
means alarms such as codepad panic, access denied and any other system alarms will not effect
the swinger shutdown count.
While the sirens are operating, the counter for the sirens is only incremented by the first zone
that causes the alarm. Any other zones that are triggered during siren run time will not effect
the counter. While the dialler is on line, its counter is only incremented by the first zone that
causes the alarm. Any other zones that are triggered while the dialler is on line will not effect
the counter.
When the swinger shutdown count (As programmed in “LOCATION 223” has been reached,
all zones that have been triggered will be locked out according to their individual lockout
settings.
System Event Timers
131
Electronics Design and Manufacturing Pty Limited
ISSUE123.DOC
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......