Defaulting The Control Panel
If the
Solution 4+4
control panel does not have "LOCATION 900" programmed as 15,
follow the procedure outlined below to successfully default the control panel back to the
factory default settings.
How To Default The Control Panel
1.
Disconnect the AC mains supply and the backup battery from the control panel.
2.
Hold down and continue to hold down the DEFAULT button located at the top of the
printed circuit board.
3.
Reconnect the AC mains to the control panel.
4.
After reconnecting the AC mains, wait for 3-5 seconds before releasing the DEFAULT
button.
You will hear the dialler seize relay (RL1) on the control panel click once and two beeps will
be heard on the remote codepad. The control panel will now need to be disarmed by using the
default Master Code (ie.
2580
).
The control panel has now been successfully defaulted back to the factory default settings.
If you hear the dialler seize relay (RL1) click four times while attempting to default the
control panel, this would indicate that the feature of defaulting the control panel has
been disabled in “LOCATION 900” on page 29. The control panel will need to be returned
to Electronics Design and Manufacturing Pty Limited for exchange where a service fee
will be charged to unlock the control panel's memory if the Installer Code is not known.
30
Solution 4+4
Installation Manual
ISSUE123.DOC
Electronics Design and Manufacturing Pty Limited
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......