Reserved
Instant Zone + Isolated In STAY Mode
This zone will act as a Instant zone when the system is armed in the AWAY Mode, but will be
automatically isolated when the system is armed in STAY Mode.
Handover Zone + Isolated In STAY Mode
This zone will act as a Handover zone when the system is armed in the AWAY Mode, but will
be automatically isolated when the system is armed in STAY Mode.
Delay-1 Zone + Isolated In STAY Mode
This zone will act as a Delay-1 zone when the system is armed in the AWAY Mode, but will
be automatically isolated when the system is armed in STAY Mode. A Delay-1 zone will have
a delay time determined by the value in "Entry Timer 1" on page 128.
Delay-2 + Isolated In STAY Mode
This zone will act as a Delay-2 zone when the system is armed in the AWAY Mode, but will
be automatically isolated when the system is armed in STAY Mode. A Delay-2 zone will have
a delay time determined by the value in "Entry Timer 2" on page 128.
Reserved
Keyswitch Zone
A Keyswitch zone is used when you need to connect a keyswitch to operate the system. Refer
to “Keyswitch Zone Options” on page 104 for selecting options such as momentary, toggle etc.
User code number 32 will be reported when arming and disarming using this method of
operation.
24 Hour Burglary Zone
A 24 Hour Burglary zone is always ready to trigger the horn speaker, bell and strobe regardless
of whether the system is in the armed or disarmed state.
24 Hour Fire Zone
A 24 Hour Fire zone is always ready to trigger the horn speaker, bell and strobe regardless of
whether the system is in the armed or disarmed state. A distinct fire sound is emitted through
the horn speaker to indicate this type of alarm condition. The fire sound is completely different
to the burglary sound.
Chime Zone
A Chime zone is not a burglary zone. It can never sound the sirens or trigger the dialler. Its
purpose is to map it to a programmable output for an indication of sealed or unsealed. Refer to
Output Event Type - Global Chime on page 122.
Chime zones require EOL resistors and they will register at a remote codepad. These zones do
not effect the operation of forced arming.
Zone Not Used
If a zone is not used, program it as a zone type of 15. This zone will never sound the sirens or
trigger the dialler. An EOL resistor is not required if this zone type is used.
6
5
7
8
9
10
11
12
13
14
15
Zone Information
101
Electronics Design and Manufacturing Pty Limited
ISSUE123.DOC
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......