Redirecting Outputs To The Codepad Buzzer
Multiple output event types can be directed to the codepad buzzer so that it may be used to
indicate any number of events.
This is achieved by selecting an output and programming it for the required output event type.
When you are satisfied that the output is functioning correctly, change the first digit of the
output event type (ie. The tens digit) by adding the value 8.
Example
30
Communications Failure
This event will operate when the dialler has made all possible attempts to reach the
base station receiver. The output will reset when the first "Kiss-Off" is received.
This output event type is not applicable for domestic reporting.
To redirect the above output event type to operate the codepad buzzer, program the output
event type as below:
0
Communications Failure
This event will operate when the dialler has made all possible attempts to reach the
base station receiver. The output will reset when the first "Kiss-Off" is received.
This output event type is not applicable for domestic reporting.
The codepad buzzer will now operate instead of the output that has been programmed. The
output is no longer functional and cannot be used for any other output event type.
Programmable Outputs
117
Electronics Design and Manufacturing Pty Limited
ISSUE123.DOC
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......