One Shot Polarities
The duration or "On" time of an output is determined by the product of the time base and the
multiplier.
If an output is required to operate for five seconds, program the time settings as follows;
2
0 5
Time Base
Multiplier
The "On" time is calculated by multiplying the time base setting (1 second) by the multiplier
value (05).
(ie. 1 x 05 = 5 seconds)
On Time
Increments
Tolerance
200 ms - 19.8 Sec’s
200 ms
+/- 200 ms
1 Sec - 99 Sec’s
1 Sec
+/- 1 Sec
1 Min - 99 Min’s
1 Min
+/- 1 Min
1 Hour - 99 Hours
1 Hour
+/- 1 Hour
Table 68: One Shot Time Settings