Overview

Thank you for purchasing the GL10-2PH high-speed differential pulse positioning module developed and 

manufactured independently by Inovance.

This product delivers 2*1 MHz high-speed differential output. It supports multiple pulse output modes, including 

dir pulse (required) or CW + CCW. It also supports homing positioning and left and right limiting. This 

product is a perfect solution for sophisticated manufacture industries which involves a large number of axes, such 

as mobile phone manufacture and TP. This guide describes the specifications, characteristics and using methods 

of the product. Please read this guide carefully before using to ensure safe usage. Visit our website (

www.inovance.

com

) for the latest version of the guide.

Safety Instructions

Safety Precautions

1. Before installing, using, and maintaining this equipment, read the safety information and precautions 

thoroughly, and comply with them during operations. 
2. To ensure the safety of humans and equipment, follow the signs on the equipment and all the safety instructions 

in this user guide. 

3. The “CAUTION”, “WARNING” and “DANGER” signs are only supplements to the safety instructions. 
4. Use this equipment according to the designated environment requirements. Damage caused by improper usage 

is not covered by warranty.
5. Inovance shall take no responsibility for any personal injuries or property damage caused by improper usage.

Safety Levels and Definitions

WARNING

: Indicates that failure to comply with the notice may result in severe personal injuries or even death.

CAUTION

: The “CAUTION” sign indicates that failure to comply with the notice may result in minor or moderate 

personal injury or damage to the equipment.
Please keep this guide well so that it can be read when necessary and forward this guide to the end user.

During control system design

WARNING

 

Provide a safety circuit outside the PLC so that the control system can still work safely once external power failure or 

PLC fault occurs.

 

◆ Add a fuse or circuit breaker because the module may smoke or catch fire due to long-time overcurrent caused by 

operation above rated current or load short-circuit.

CAUTION

 

◆ An emergency stop circuit, a protection circuit, a forward/reverse operation interlocked circuit, and a upper position 

limit and lower position limit interlocked circuit must be set in the external circuits of PLC to prevent damage to the 

machine.

 

◆ To ensure safe operation, for the output signals that may cause critical accidents, please design external protection 

circuit and safety mechanism;

 

◆ Once PLC CPU detects abnormality in the system , all outputs may be closed; however, when a fault occurs in the 

controller circuit, the output may not be under control. Therefore, it is necessary to design an appropriate external 

control circuit to ensure normal operation;

 

◆ If the PLC output units such as relays or transistors are damaged, the output may fail to switch between ON and OFF 

states according to the commands;

 

The PLC is designed to be used in indoor electrical environment (overvoltage category II). The power supply must have 

a system-level lightning protection device, assuring that overvoltage due to lightning shock cannot be applied to the 

PLC power supply input terminals, signal input terminals and output terminals and so forth, so as to avoid damage to 

the equipment.

1

Installation

WARNING

 

Installation must be carried out by the specialists who have received the necessary electrical training and understood 

enough electrical knowledge.

 

◆ Disconnect all external power supplies of the system before removing/installing the module. Failure to do so may 

result in electric shock, module fault or malfunction.

 

◆ Do not use the PLC where there are dust, oil smoke, conductive dust, corrosive or combustible gases, or exposed to 

high temperature, condensation, wind & rain, or subject to vibration and impact. Electric shock, fire and malfunction 

may also result in damage or deterioration to the product.

 

The PLC is open-type equipment that must be installed in a control cabinet with lock (cabinet housing protection 

>IP20). Only the personnel who have received the necessary electrical training and understood enough electrical 

knowledge can open the cabinet.

CAUTION

 

◆ Prevent metal filings and wire ends from dropping into ventilation holes of the PLC during installation. Failure to 

comply may result in fire, fault and malfunction.

 

◆ Ensure there are no foreign matters on ventilation surface. Failure to comply may result in poor ventilation, which may 

cause fire, fault and malfunction.

 

◆ Ensure the module is connected to the respective connector securely and hook the module firmly. Improper 

installation may result in malfunction, fault or fall-off.

Wiring

WARNING

 

Wiring must be carried out by personnel who have received the necessary electrical training and understood enough 

electrical knowledge.

 

◆ Disconnect all external power supplies of the system before wiring. Failure to comply may result in electric shock, 

module fault or malfunction.

 

◆ Install the terminal cover attached to the product before power-on or operation after wiring is completed. Failure to 

comply may result in electric shock

 

Perform good insulation on terminals so that insulation distance between cables will not reduce after cables are 

connected to terminals. Failure to comply may result in electric shock or damage to the equipment.

CAUTION

 

◆ Prevent dropping metal filings and wire ends drop into ventilation holes of the PLC at wiring. Failure to comply may 

result in fire, fault and malfunction.

 

◆ The external wiring specification and installation method must comply with local regulations. For details, see the wiring 

section in this guide.

 

◆ To ensure safety of equipment and operator, use cables with sufficient diameter and connect the cables to ground 

reliably.

 

◆ Ensure that all cables are connected to the correct interface. Failure to comply may result in module and external 

equipment fault.

 

◆ Tighten bolts on the terminal block in the specified torque range. If the terminal is not tight, short-circuit, fire or 

malfunction may be caused. If the terminal is too tight, fall-off, short-circuit, fire or malfunction may be caused.

 

◆ If the connector is used to connect with external equipment, perform correct crimping or welding with the tool 

specified by manufacturer. If connection is in poor contact, short-circuit, fire or malfunction may be caused.

 

◆ A label on the top of the module is to prevent foreign matters entering the module. Do not remove the label during 

wiring. Remember to remove it before system operation, facilitating ventilation.

 

◆ Do not bundle control wires, communication wires and power cables together. They must be run with distance of more 

than 100 mm. Otherwise, noise may result in malfunction.

 

◆ Select shielded cable for high-frequency signal input/output in applications with serious interference so as to enhance 

system anti-interference ability.

Operation and Maintenance

WARNING

 

◆ Maintenance & inspection must be carried out by personnel who have the necessary electrical training and experience.

 

◆ Do not touch the terminals while the power is on. Failure to comply may result in electric shock or malfunction.

 

◆ Disconnect all external power supplies of the system before cleaning the module or re-tightening screws on the terminal 

block or screws of the connector. Failure to comply may result in electric shock.

 

◆ Disconnect all external power supplies of the system before removing the module or connecting/removing the 

communication wirings. Failure to comply may result in electric shock or malfunction.

CAUTION

 

◆ Get with the guide and ensure safety before online modification, forcible output, and RUN/STOP operation.

 

◆ Disconnect the power supply before installing/removing the extension card.

Disposal

CAUTION

 

◆ Treat scrapped module as industrial waste. Dispose the battery according to local laws and regulations.

Product Information

 

Model Number and Nameplate

(-1)

.BSL

4FSJFT

.BSL

%FTDSJQUJPO

(

.BSL

0VUQVUT

.BSL

.PEVMF5ZQF

1)

(FOFSBM.PEVMF

-

-PDBMNPEVMF

.OMNYVKKJ*/,,U[ZV[Z

V[RYKVUYOZOUTOTM

19011285    A01

.PEFM
3BUFEJOQVU
3BUFEPVUQVU

4FSJBM/P

/BNFQMBUF

.0%&-盘(-1)

108&3*/165盘/0/&

065165盘/0/&

9999999999999999

7FSTJPO/P

7&399999

9999999999999999

Figure 1 Description of model number and nameplate

Model

Category

Description

Applicable 

Model

GL10-2PH

Local I/O module

For local bus expansion, 2 high-speed differential output 

pulse positioning modules, output frequency 1 MHz, 8 

ordinary inputs

H3U series

 

■ External Interface

No. Interface Name

Function

State indicator

PWR

Power indicator

Green

ON when power supply is 

switched on

RUN

Normal operation 

indicator

Green

ON when power supply is 

switched on

ERR

Fault indicator

Red

ON when the module is faulty

Signal indicator

CH0/1

Indicator

Green

On when channel 0/1 is ready 

to output

A/B

Pulse+direction 

Indicator

Green

--

X0-X3

Digital input indicator

Green

On when the input signal is 

active

Local expansion 

module back-end 

interface

Connect back-end module, not supporting hot plugging

User terminal

Pulse output terminal, see "Electrical Design Reference"

Front-end 

interface of local 

expansion module

Connects front-end module, not supporting hot plugging

 

■ General Specifications

Item

Specifications

Rated operating voltage

24 VDC (20.4 VDC to 28.8 VDC) (–15% to +20%)

Output channel

2

User terminal

36-pin leaf spring terminal, for both I/O and power supply

2

3

GL10

-2PH High-Speed Differential

Pulse Positioning Module

User Guide