Normally Open, One Shot Low With Alarm
This one shot polarity is normally open circuit and will switch to zero volts when the event
occurs. The output will switch back to open circuit once the one shot time has expired, when
the event has returned to normal or when the system has been disarmed.
This polarity is ideally suited for the operation of strobe lights as they can be programmed (Up
to 99 hours) to reset and prevent them from burning out or becoming annoying to others from
prolonged operation.
Normally Open, Latching Low
This polarity is normally open circuit and will switch to zero volts when the event occurs. The
output will switch back to open circuit once the
7
button on the remote codepad is held down
until two beeps are heard. Time parameters are not applicable to this polarity.
Normally Low, Going Open
This polarity is normally zero volts and will switch to open circuit when the event occurs. The
output will switch back to zero volts when the event has restored. Time parameters are not
applicable to this polarity.
Normally Low, Pulsing Open
This polarity is normally zero volts and will switch to pulsing open circuit when the event
occurs. The output will switch back to zero volts when the event has restored. Time
parameters vary the "Off" time of the pulse.
Normally Low, One Shot Open
This one shot polarity is normally zero volts and will switch to open circuit when the event
occurs. The output will switch back to zero volts when the time parameter has expired. This
one shot time setting will always run its full duration and cannot be manually reset.
Normally Low, One Shot Open With Retrigger
This one shot polarity is normally zero volts and will switch to open circuit when the event
occurs. Every time the event occurs, it will restart the one shot timer. The output will switch
back to zero volts once the one shot time has expired.
Normally Low, One Shot Open With Reset
This one shot polarity is normally zero volts and will switch to open circuit when the event
occurs. The output will switch back to zero volts when the one shot time has expired or when
the event has returned to normal. This means the one shot timer can be shortened regardless of
the time setting.
Normally Low, One Shot Open With Alarm
This one shot polarity is normally zero volts and will switch to open circuit when the event
occurs. The output will switch back to zero volts when the one shot time has expired, when the
event has returned to normal or when the system has been disarmed. This means that the one
shot timer can be shortened regardless of the time setting.
Normally Low, Latching Open
This polarity is normally zero volts and will switch to open circuit when the event occurs. The
output will switch back to zero volts once the
7
button on the remote codepad has been held
down until two beeps are heard. Time parameters are not applicable to this polarity.
6
7
8
9
10
11
12
13
14
124
Solution 4+4
Installation Manual
ISSUE123.DOC
Electronics Design and Manufacturing Pty Limited
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......