Domestic Reporting Format
The locations of the primary telephone number and secondary telephone number which are
normally used for base station reporting can be added together making provision to store up to
32 digits for domestic dialling format. The 32 locations are now used to store any number of
telephone numbers and subject to the length of each telephone number, it is possible to store 3
or more different phone numbers for domestic dialling.
A four second pause may be inserted anywhere in the telephone number by programming the
number ‘13’. The four second pauses can only be programmed by the installer as the Master
Code holder has no access to this function.
Domestic Dialling Function
When the control panel has activated into alarm condition, it will commence dialling the first
programmed telephone number. If a busy or engaged tone has been detected, the control panel
will hang up and commence dialling the second telephone number (if one is programmed).
The first call however will be counted as one unsuccessful dialling attempt. If the second
telephone number is also busy or an engaged tone is detected, the control panel will hang up
and commence dialling the third telephone number (if one is programmed).
If a busy tone is not detected, the control panel will assume that the phone has been answered
and will begin sending its transmission. The transmission consists of a siren tone followed by
a unit identification beep. The identification beep will allow the customer to verify which
control panel made the call if more than one control panel is reporting to the same telephone
number. The identification beep is programmed in "LOCATION 055" of the Subscriber ID
Number.
After the identification beep, a long pause will follow allowing you to acknowledge the call. If
the call is not acknowledged during the pause, the sequence of the siren tone, the identification
beep and the pause will continue until you acknowledge the call or until the control panel
hangs up after two minutes has expired.
A maximum of 6 calls per alarm event will be made when the control panel has been set
up for "Domestic Dialling Format". This count includes any unsuccessful calls. The
counter will be reset if the zone retriggers and a further 6 attempts will be made. The
control panel will stop dialling after 6 attempts or 3 successful calls. The control panel
will also stop dialling if a valid user code has been entered at the remote codepad.
How To Acknowledge Domestic Dialling
Once the call has been received, if it is not acknowledged by pressing the
*
button on a touch
tone telephone or by using the Phone Controller (CC911), the control panel will continue to
send its transmission for a period of 2 minutes. It will then hang up and commence dialling the
next telephone number. If the call is acknowledged, the control panel will hang up and no
further calls will be made for that event.
76
Solution 4+4
Installation Manual
ISSUE123.DOC
Electronics Design and Manufacturing Pty Limited
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......