System Status Information
This section covers features that are involved with the basic house keeping of the system. This
includes monitoring of the zones - whether they are isolated from the system or more
importantly that they are actually operating, the status of both the AC mains and DC power to
the system and codepad generated alarms activated by the user.
Zone Bypass Reports
LOCATION 152 – 153
99
Location
Description
152
Alarm Or Expansion Code In 4+2 Format
153
Restore Code In 4+2 Format
Table 54: Zone Status - Bypass Report Locations
A zone is bypassed when it is manually isolated. Refer to “Isolating Zones” on page 41 for
information on isolating zones. A "Zone Bypass" report (Contact ID Event Code 570) will be
transmitted at the end of exit time for any zone that has been manually isolated. 24 hour zones
cannot be manually isolated, therefore they will never transmit bypass reports.
A "Zone Bypass Restore" report will be transmitted when the system has been disarmed. If
bypass restore is not programmed, it can be assumed that it will transmit a bypass restore report
when an opening report is transmitted. All bypassed zones are automatically cleared when the
system has been disarmed.
The bypass code parameter is used as the expansion digit in 4+2 Formats. It has no effect on
Contact ID Format as a zone bypass will always be reported on event code 570.
If "Zone Bypass" reports are not required, program "LOCATION 152 – 153" with a zero.
Zone Trouble Reports
LOCATION 154 – 155
99
Location
Description
154
Alarm Or Expansion Code In 4+2 Format
155
Restore Code In 4+2 Format
Table 55: Zone Status - Trouble Report Locations
A zone is in trouble when it is unsealed at the end of exit time. A "Sensor Trouble" report
(Contact ID Event Code 380) will be transmitted to indicate that one or more zones have been
automatically isolated by the system. 24 hour zones that are unsealed at the end of exit time
will not transmit a "Sensor Trouble" report as the restore for that zone is still outstanding.
A "Sensor Trouble" restore report will be transmitted for burglary zones when the zone reseals
or when the system is next disarmed (which ever happens first). A 24 hour zone will only
transmit a restore signal when it has resealed.
The trouble code parameter is used as the expansion digit in 4+2 Format. It has no effect on
Contact ID Format as a "Sensor Trouble" report will always be reported on event code 380.
If "Sensor Trouble" reports are not required, program "LOCATION 154 – 155" with a zero.
If a tamper zone is unsealed at the end of exit time, a Contact ID Event Code 383 will be
transmitted.
108
Solution 4+4
Installation Manual
ISSUE123.DOC
Electronics Design and Manufacturing Pty Limited
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......