Command 965 - Set Up Domestic Dialling Format
Command 965 has been added to make the set up of the domestic dialling format a one step
operation. Refer to page 76 for more information on Domestic Reporting Format.
After Installer's Programming Mode has been accessed, enter command
965
followed by
the
#
button. This will automatically set the following locations in bold below. No other
locations will be changed when command 965 has been issued.
Location
Description
Setting
LOCATION 49
Handshake Tone
2 (1400 Hz)
LOCATION 50
Transmission Format
11 (Domestic)
LOCATION 052 – 055
Subscriber ID Number
0, 0, 0, 1 (1 Beep)
LOCATION 104 – 111
Zone 1
2, 0, 0, 0, 0, 3, 0, 1 (Delay-1)
LOCATION 112 - 119
Zone 2
1, 0, 0, 0, 0, 3, 0, 1 (Handover)
LOCATION 120 - 127
Zone 3
1, 0, 0, 0, 0, 3, 0, 1 (Handover)
LOCATION 128 - 135
Zone 4
12, 0, 0, 0, 0, 3, 0, 1 (24 Hour)
LOCATION 152 - 153
Bypass Reports
0, 0 (Not Used)
LOCATION 154 - 155
Trouble Reports
0, 0 (Not Used)
LOCATION 156 - 159
Codepad Duress
0, 0, 0, 0 (Not Used)
LOCATION 160 - 163
Codepad Panic
0, 0, 0, 0 (Not Used)
LOCATION 164 - 167
Access Denied
0, 0, 0, 0 (Not Used)
LOCATION 168 - 171
AC Fail
0, 0, 0, 0 (Not Used)
LOCATION 172 - 175
Low Battery
0, 0, 0, 0 (Not Used)
LOCATION 176 - 179
Sensor Watch
0, 0, 0, 0 (Not Used)
LOCATION 180 - 181
Open/Close Reports
0, 0 (Not Used)
LOCATION 182 – 185
Test Report Time
0, 0, 0, 9 (Not Used)
Table 5: Command 965 Defaults
As you can see from the table above, all reporting other than zone alarms have been disabled.
The handshake tone has been set for 1400 Hz tone acknowledgment and the Subscriber ID
Number has been set for one identification beep. The zone reporting has been set so that any
zone that triggers an alarm condition will only report when the alarm occurs, the zone restore
report will not report as there is no separate indications for zone alarm reports and zone alarm
restore reports.
Programming
27
Electronics Design and Manufacturing Pty Limited
ISSUE123.DOC
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......