Hand Held Dialler Tester (DD901)
The hand held dialler tester simulates a base station for testing of the control panel's dialling
functions. It communicates in most formats.
Cellular Diallers
The cellular dialler when connected to the control panel will transmit alarm information via the
cellular phone network to the base station receiver when a land telephone line is not present or
has been tampered with.
PS100 Power Supply Module (PS100
)
The PS100 Power Supply Module has been designed for applications requiring 13.8 volts DC
at currents of up to 1 Amp and must be used in conjunction with the TF008 - 18 volt AC plug
pack.
The unit comes complete with our standard, fully short circuit proof, power out and battery
charging terminals as well as a DC LED indicator and AC mains fail output. For situations
requiring an uninterrupted power source, a rechargeable sealed lead-acid battery can be
connected. In the event of a mains failure, the power supply will switch to battery power
without interrupting the load being supplied.
TF008 Plug Pack (TF008)
The TF008 plug packs have been designed to be used with the EDM control panels and the
PS100 Power Supply Module. The plug pack includes built in thermal fuses which under
overload or fault conditions will blow and eliminate any possible fire threat due to excessive
heat build up inside the casing.
The TF008 plug pack incorporates a three wire flying lead that enables a mains earth
connection to be made between the equipment and the plug pack. This connection may be
required for lightning protection on equipment that is connected to phone lines or for safety
reasons such as earthing of metal enclosures.
Solution Codepad Mimic Board (CC820)
The Solution Codepad Mimic Board (CC820) has been designed to allow you to have a
separate output indicator for each indicator found on the remote codepad. This will be useful
to remotely display system status information.
Solution Relay Output Interface (CC892)
The Solution Relay Output Interface (CC892) has been designed to allow up to an additional 8
relay outputs to be connected to a Solution control panel. This will be useful to remotely
display system status information.
The 3 way DIP switch on the board is used to select the data that is to be displayed on the
relays. Multiple interfaces may be connected in parallel for different data displays.
2 Wire Smoke Detector Interface (FA101)
The 2 Wire Smoke Detector Interface (FA101) has been designed to allow high quality 2 wire,
24 volt DC smoke detectors to be easily connected to the Solution range of control panels. The
interface provides the 24 volts required to power the smoke detector and also provides a relay
output that is used to trigger the control panel. Multiple detectors may be connected to the
same interface.
Optional Equipment
143
Electronics Design and Manufacturing Pty Limited
ISSUE123.DOC
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......